Dishwasher (under-bench)
Adelaide showroom & customer experience centre · Showroom
Failed — action recorded, retest pending
Test history
- 21 Aug 2025FAIL
Measurements (3)
Measurement Value Limit applied Outcome Visual inspection Fail — FAIL Earth continuity 0.19 Ω ≤ 1.0 Ω PASS Insulation resistance 0.62 MΩ ≥ 1.0 MΩ FAIL - 21 Aug 2023PASS
Measurements (3)
Measurement Value Limit applied Outcome Visual inspection Pass — PASS Earth continuity 0.19 Ω ≤ 1.0 Ω PASS Insulation resistance 0.62 MΩ ≥ 1.0 MΩ PASS
Test events are permanent records. Corrections appear as new entries that supersede the original — the original stays visible.
Failures and actions
Awaiting retest
Insulation resistance below limit (0.62 MΩ, limit ≥ 1.0 MΩ)
- Customer: Item replaced with new unit; old unit withdrawn and tagged out.
Identity
- PS-B28FZ
- SA-2599
- Class I
- Adelaide showroom & customer experience centre
- Showroom
- 24 months