Skip to content

PlanetSafe · Customer Portal

All assets

PS-VWPJ5

Kettle

Collins St office · Level 2 office

Failed — action required

Test history

2 recorded events
  1. 14 May 2026FAIL

    S. Nguyen · Imported from tester export

    Measurements (3)
    MeasurementValueLimit appliedOutcome
    Visual inspectionFail—FAIL
    Earth continuity0.12 Ω≤ 1.0 ΩPASS
    Insulation resistance0.62 MΩ≥ 1.0 MΩFAIL
  2. 14 May 2025PASS

    S. Nguyen · Imported from tester export

    Measurements (3)
    MeasurementValueLimit appliedOutcome
    Visual inspectionPass—PASS
    Earth continuity0.12 Ω≤ 1.0 ΩPASS
    Insulation resistance0.62 MΩ≥ 1.0 MΩPASS

Test events are permanent records. Corrections appear as new entries that supersede the original — the original stays visible.

Failures and actions

  • Action required

    Recorded 14 May 2026

    Insulation resistance below limit (0.62 MΩ, limit ≥ 1.0 MΩ)

Identity

PlanetSafe asset ID
PS-VWPJ5
Your reference
VIC-6669
Equipment class
Class I
Site
Collins St office
Area
Level 2 office
Retest interval
12 months
Next due
14 May 2027